CVE-2026-54470
Dell Unisphere for PowerMax, version(s) 10.3.0.5 and prior contain(s) an Improper Restriction of XML External Entity Reference vulnerability
CVSS
5.3
Medium
EPSS
0.3%
p23
KEV
—
Exploit Today
7
0-100
Published: Jul 10, 2026 · Last modified: Jul 16, 2026 · CWE-611
0.2%EPSS · 30 days0.3%
2026-08-132026-09-09
Dell Unisphere for PowerMax, version(s) 10.3.0.5 and prior contain(s) an Improper Restriction of XML External Entity Reference vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to Unauthorized access.
CVECVSSEPSSKEVRExploitTitleMod.
CVE-2026-84941——
———An information disclosure vulnerability in the SAML Single Sign-On (SSO) functionality of Omada Controller allows an authenticated user with SAML configuration privileges to access sensitive information due to insufficient validation of user-supplied SAML metadata. Successful exploitation could result in unauthorized disclosure of sensitive information.2hCVE-2026-195965.9 MED—
———An XML External Entity (XXE) vulnerability exists in the XML collector of multiple versions of OpenNMS Meridian and Horizon. When OpenNMS collects XML from a source whose response is attacker-controlled (for example a compromised monitored host or an HTTP man-in-the-middle position), the collector's XML parser resolves external entities and external DTDs. This allows an attacker to read files accessible to the OpenNMS service account, including database credentials, and to induce out-of-band requests.
The solution is to upgrade to Meridian 2024.3.13, 2025.0.10 and Horizon 36.0.4 or newer. Meridian and Horizon installation instructions state that they are intended for installation within an organization's private networks and should not be directly accessible from the Internet.5hCVE-2026-19614—14.0%
——4The API is prone to XML external entity (XXE) injection. By default, XML external entity support is enabled.
This issue affects NanoXML: 2.2.3.1dCVE-2026-713757.4 HIG15.9%
——5Improper restriction of XML external entity reference vulnerability in Cosminexus Component Container.
This issue affects Cosminexus Component Container: from 11-70-01 before 11-70-03, from 11-60 before 11-60-03, from 11-50 through 11-50-03, from 11-40 through 11-40-03, from 11-30 through 11-30-08, from 11-20 before 11-20-10, from 11-10 through 11-10-11, from 11-00 before 11-00-13, from 09-87 before 09-87-10, from 09-80 before 09-80-05, from 09-70 before 09-70-28, from 09-50 through 09-50-22, and from 09-00 through 09-00-18.3dCVE-2026-769588.5 HIG12.9%
——4SAP Integration Suite does not sufficiently validate XML documents accepted from untrusted sources in certain internal components. An attacker with low privileges could submit specially crafted XML payloads containing malicious external entity declarations. Successful exploitation could allow the attacker to read sensitive file contents from the server and expose them through monitoring or logging output, resulting in a high impact on confidentiality. It could also lead to resource exhaustion, causing a low impact on availability. There is no impact on integrity.2dCVE-2026-174445.3 MED21.5%
——6IBM App Connect Enterprise 13.0.1.0 through 13.0.8.1, and 12.0.1.0 through 12.0.12.28 and IBM Integration Bus for z/OS 10.1.0.0 through 10.1.0.7 could allow a remote authenticated attacker to obtain sensitive information due to an XML external entity (XXE) injection.5h