CVE-2026-71929
Multiple DrayTek VigorSwitch models contain a command injection vulnerability in the setDevProto function. The vulnerability is caused by in
CVSS
7.2
High
EPSS
—
KEV
—
Exploit Today
0
0-100
Published: Aug 24, 2026 · Last modified: Aug 24, 2026 · CWE-78
Not enough EPSS history yet.
Multiple DrayTek VigorSwitch models contain a command injection vulnerability in the setDevProto function. The vulnerability is caused by insufficient filtering of the username and password fields before command execution. A remote attacker can trigger this vulnerability via crafted input to execute arbitrary commands with root privileges. Exploitation requires valid administrative credentials for the device's web management interface.
CVECVSSEPSSKEVRExploitTitleMod.
CVE-2026-784305.3 MED—
——0A vulnerability was detected in sworddut mcp-ffmpeg-helper 0.1.0/0.1.1/0.2.1. This affects the function handleToolCall of the file src/tools/handlers.ts of the component Tool Handler. The manipulation of the argument format results in os command injection. Attacking locally is a requirement. The exploit is now public and may be used. The project was informed of the problem early through an issue report but has not responded yet.1dCVE-2026-78541——
——0A stored OS
command injection vulnerability exists in the parent-control module of TP-Link
Archer BE3600 V1. An authenticated adjacent attacker with administrative access
may store a crafted profile name containing shell metacharacters, which is
later processed unsafely during daily cloud report generation and may result in
arbitrary command execution.
Successful
exploitation may allow command execution on the affected device with potential
impact to device confidentiality, integrity, and availability.1dCVE-2026-9254——
——0An unauthenticated OS command injection vulnerability exists in the parental control functionality of Archer BE800 V1, BE3600 V1, and AX75 V1 due to improper filtering and neutralization of special characters in certain parameters. A LAN-based attacker can inject arbitrary commands and execute them with root privileges.
Successful exploitation may result in complete device compromise and impact the confidentiality, integrity, and availability of the affected device and network traffic.1dCVE-2026-719437.2 HIG—
——0Multiple DrayTek VigorSwitch models contain a command injection vulnerability in the setDevNet function. The vulnerability is caused by insufficient filtering of the username and password fields before command execution. A remote attacker can trigger this vulnerability via crafted input to execute arbitrary commands with root privileges. Exploitation requires valid administrative credentials for the device's web management interface.1dCVE-2026-719317.2 HIG—
——0Multiple DrayTek VigorSwitch models contain a command injection vulnerability in the tftp_upgrade function. The vulnerability is caused by insufficient filtering before the filename field is concatenated into a command. A remote attacker can trigger this vulnerability via crafted input to execute arbitrary commands with root privileges. Exploitation requires valid administrative credentials for the device's web management interface.1dCVE-2026-719307.2 HIG—
——0Multiple DrayTek VigorSwitch models contain a command injection vulnerability in the setTime function. The vulnerability is caused by insufficient filtering of the username and password fields before command execution. A remote attacker can trigger this vulnerability via crafted input to execute arbitrary commands with root privileges. Exploitation requires valid administrative credentials for the device's web management interface.1d