PULSE
LIVE0signals / 24h
FEED
vulnKEV agrega CVE-2026-59822 — BerriAI / LiteLLMvulnKEV agrega CVE-2026-48710 — Kludex / StarlettevulnKEV agrega CVE-2026-49869 — Kestra / Kestra OSSvulnKEV agrega CVE-2026-82329 — JFrog / ArtifactoryvulnKEV agrega CVE-2026-9586 — Sangoma / SwitchvoxvulnKEV agrega CVE-2026-83548 — SonicWall / SMA1000 AppliancesvulnKEV agrega CVE-2026-83549 — SonicWall / SMA1000 AppliancesvulnKEV agrega CVE-2026-82078 — PaperCut / NG/MFvulnKEV agrega CVE-2026-81578 — PaperCut / NG/MFvulnKEV agrega CVE-2023-49105 — ownCloud / ownCloudvulnKEV agrega CVE-2026-53362 — Linux / KernelvulnKEV agrega CVE-2026-66384 — JFrog / ArtifactoryvulnKEV agrega CVE-2021-23758 — Ajax.NET Professional / Ajax.NET ProfessionalvulnKEV agrega CVE-2015-3246 — Red Hat / LibuservulnKEV agrega CVE-2026-59822 — BerriAI / LiteLLMvulnKEV agrega CVE-2026-48710 — Kludex / StarlettevulnKEV agrega CVE-2026-49869 — Kestra / Kestra OSSvulnKEV agrega CVE-2026-82329 — JFrog / ArtifactoryvulnKEV agrega CVE-2026-9586 — Sangoma / SwitchvoxvulnKEV agrega CVE-2026-83548 — SonicWall / SMA1000 AppliancesvulnKEV agrega CVE-2026-83549 — SonicWall / SMA1000 AppliancesvulnKEV agrega CVE-2026-82078 — PaperCut / NG/MFvulnKEV agrega CVE-2026-81578 — PaperCut / NG/MFvulnKEV agrega CVE-2023-49105 — ownCloud / ownCloudvulnKEV agrega CVE-2026-53362 — Linux / KernelvulnKEV agrega CVE-2026-66384 — JFrog / ArtifactoryvulnKEV agrega CVE-2021-23758 — Ajax.NET Professional / Ajax.NET ProfessionalvulnKEV agrega CVE-2015-3246 — Red Hat / Libuser
← All CVEs
CVE WatchSep 4, 2026

CVE-2026-80754

In the Linux kernel, the following vulnerability has been resolved: Input: synaptics-rmi4 - fix F55 transmitter electrode count typo Durin

CVSS

7.8

High

EPSS

KEV

Exploit Today

0-100

Published: Sep 3, 2026 · Last modified: Sep 4, 2026

EPSS · 30d

Not enough EPSS history yet.

Technical description

In the Linux kernel, the following vulnerability has been resolved: Input: synaptics-rmi4 - fix F55 transmitter electrode count typo During F55 sensor detection, the transmitter (TX) electrode count was incorrectly assigned the value of the receiver (RX) electrode count due to copy-paste typos. This incorrect value was then propagated to the driver data and used by F54 to determine the diagnostics report size. On devices with more RX than TX electrodes, this inflated the perceived TX count, leading to incorrect report size calculations and potential out-of-bounds buffer accesses. Fix the typos by correctly assigning the TX electrode counts.

Official references
Related CVEs

No related CVEs by CWE or product.