PULSE
LIVE0signals / 24h
FEED
vulnKEV agrega CVE-2026-59822 — BerriAI / LiteLLMvulnKEV agrega CVE-2026-48710 — Kludex / StarlettevulnKEV agrega CVE-2026-49869 — Kestra / Kestra OSSvulnKEV agrega CVE-2026-82329 — JFrog / ArtifactoryvulnKEV agrega CVE-2026-9586 — Sangoma / SwitchvoxvulnKEV agrega CVE-2026-83548 — SonicWall / SMA1000 AppliancesvulnKEV agrega CVE-2026-83549 — SonicWall / SMA1000 AppliancesvulnKEV agrega CVE-2026-82078 — PaperCut / NG/MFvulnKEV agrega CVE-2026-81578 — PaperCut / NG/MFvulnKEV agrega CVE-2023-49105 — ownCloud / ownCloudvulnKEV agrega CVE-2026-53362 — Linux / KernelvulnKEV agrega CVE-2026-66384 — JFrog / ArtifactoryvulnKEV agrega CVE-2021-23758 — Ajax.NET Professional / Ajax.NET ProfessionalvulnKEV agrega CVE-2015-3246 — Red Hat / LibuservulnKEV agrega CVE-2026-59822 — BerriAI / LiteLLMvulnKEV agrega CVE-2026-48710 — Kludex / StarlettevulnKEV agrega CVE-2026-49869 — Kestra / Kestra OSSvulnKEV agrega CVE-2026-82329 — JFrog / ArtifactoryvulnKEV agrega CVE-2026-9586 — Sangoma / SwitchvoxvulnKEV agrega CVE-2026-83548 — SonicWall / SMA1000 AppliancesvulnKEV agrega CVE-2026-83549 — SonicWall / SMA1000 AppliancesvulnKEV agrega CVE-2026-82078 — PaperCut / NG/MFvulnKEV agrega CVE-2026-81578 — PaperCut / NG/MFvulnKEV agrega CVE-2023-49105 — ownCloud / ownCloudvulnKEV agrega CVE-2026-53362 — Linux / KernelvulnKEV agrega CVE-2026-66384 — JFrog / ArtifactoryvulnKEV agrega CVE-2021-23758 — Ajax.NET Professional / Ajax.NET ProfessionalvulnKEV agrega CVE-2015-3246 — Red Hat / Libuser
← All CVEs
CVE WatchSep 4, 2026

CVE-2026-80874

In the Linux kernel, the following vulnerability has been resolved: arm64: dts: renesas: ironhide: Describe inline ECC carveouts The DBSC5

CVSS

No CVSS

EPSS

KEV

Exploit Today

0-100

Published: Sep 4, 2026 · Last modified: Sep 4, 2026

EPSS · 30d

Not enough EPSS history yet.

Technical description

In the Linux kernel, the following vulnerability has been resolved: arm64: dts: renesas: ironhide: Describe inline ECC carveouts The DBSC5 DRAM controller protects DRAM content using inline ECC. The inline ECC utilizes areas of DRAM for its operation, which are in the DRAM address range, but must not be accessed or modified. Describe the inline ECC carveout areas used by the DBSC5 controller on this hardware as reserved-memory, which must not be accessed. Include DRAM areas which are unprotected by ECC as well, those are parts of the DRAM which directly precede the ECC carveout. In case of high DRAM utilization, unless the inline ECC carveouts are properly reserved, Linux may use and corrupt the memory used by the DBSC5 DRAM controller for inline ECC, which would lead to the system becoming unstable.

Official references
Related CVEs

No related CVEs by CWE or product.