PULSE
LIVE0signals / 24h
FEED
vulnKEV agrega CVE-2026-85046 — Google / Chromium V8vulnKEV agrega CVE-2026-59822 — BerriAI / LiteLLMvulnKEV agrega CVE-2026-48710 — Kludex / StarlettevulnKEV agrega CVE-2026-49869 — Kestra / Kestra OSSvulnKEV agrega CVE-2026-82329 — JFrog / ArtifactoryvulnKEV agrega CVE-2026-9586 — Sangoma / SwitchvoxvulnKEV agrega CVE-2026-83548 — SonicWall / SMA1000 AppliancesvulnKEV agrega CVE-2026-83549 — SonicWall / SMA1000 AppliancesvulnKEV agrega CVE-2026-82078 — PaperCut / NG/MFvulnKEV agrega CVE-2026-81578 — PaperCut / NG/MFvulnKEV agrega CVE-2023-49105 — ownCloud / ownCloudvulnKEV agrega CVE-2026-53362 — Linux / KernelvulnKEV agrega CVE-2026-66384 — JFrog / ArtifactoryvulnKEV agrega CVE-2021-23758 — Ajax.NET Professional / Ajax.NET ProfessionalvulnKEV agrega CVE-2026-85046 — Google / Chromium V8vulnKEV agrega CVE-2026-59822 — BerriAI / LiteLLMvulnKEV agrega CVE-2026-48710 — Kludex / StarlettevulnKEV agrega CVE-2026-49869 — Kestra / Kestra OSSvulnKEV agrega CVE-2026-82329 — JFrog / ArtifactoryvulnKEV agrega CVE-2026-9586 — Sangoma / SwitchvoxvulnKEV agrega CVE-2026-83548 — SonicWall / SMA1000 AppliancesvulnKEV agrega CVE-2026-83549 — SonicWall / SMA1000 AppliancesvulnKEV agrega CVE-2026-82078 — PaperCut / NG/MFvulnKEV agrega CVE-2026-81578 — PaperCut / NG/MFvulnKEV agrega CVE-2023-49105 — ownCloud / ownCloudvulnKEV agrega CVE-2026-53362 — Linux / KernelvulnKEV agrega CVE-2026-66384 — JFrog / ArtifactoryvulnKEV agrega CVE-2021-23758 — Ajax.NET Professional / Ajax.NET Professional
← All CVEs
CVE WatchSep 5, 2026

CVE-2026-86148

A security flaw has been discovered in Tenda CP3 27.5.57.101. This vulnerability affects the function SystemAsh of the file Apis/system.c of

CVSS

9.1

Critical

EPSS

2.5%

p83

KEV

Exploit Today

25

0-100

Published: Sep 5, 2026 · Last modified: Sep 5, 2026 · CWE-77 · CWE-78

EPSS · 30d

Not enough EPSS history yet.

Technical description

A security flaw has been discovered in Tenda CP3 27.5.57.101. This vulnerability affects the function SystemAsh of the file Apis/system.c of the component Kylin. The manipulation of the argument AlarmVoiceURL results in os command injection. It is possible to launch the attack remotely.

Official references
Related CVEs
CVECVSSEPSSKEVRExploitTitleMod.
CVE-2026-801277.2 HIG
Dell SCG 5.0 Appliance versions prior to 5.36.00.16 and Dell SCG 5.0 Application versions prior to 5.36.00.00, contains an Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability. A high privileged attacker with remote access could potentially exploit this vulnerability, leading to elevation of privileges.3h
CVE-2026-784886.5 MED
Dell SCG 5.0 Appliance versions prior to 5.36.00.16 and Dell SCG 5.0 Application versions prior to 5.36.00.00, contains an Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to command execution.4h
CVE-2026-198438.4 HIG
A flaw was found in 389-ds-base. The Cockpit 389 Console's LDAP editor constructs an ldapsearch command by embedding an LDAP entry's distinguished name (DN) into a shell command string without proper escaping. An LDAP user with delegated privileges to create or rename directory entries could craft a malicious DN containing shell metacharacters. When a Cockpit administrator subsequently views the entry in the 389 Console, the embedded shell command executes with root privileges on the directory server host.4h
CVE-2026-864278.8 HIG
LibreNMS before 26.8.0 contains an argument injection vulnerability in the graph_title parameter that allows authenticated attackers to inject arbitrary rrdtool arguments by breaking out of double-quote escaping. Attackers can inject DEF and LINE arguments to read RRD files from unauthorized devices, or use newline injection to execute arbitrary rrdtool commands, bypassing per-device authorization checks.6h
CVE-2026-614097.3 HIG
Dell Secure Connect Gateway (SCG) 5.0 Application, versions prior to 5.36.00.00, contains an Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability. An unauthenticated attacker with remote access could potentially exploit this vulnerability, leading to remote execution.6h
CVE-2026-862999.9 CRI
0A vulnerability was detected in Linksys RE7000 2.0.15. This affects the function platform_event_pingTest of the file /cgi-bin/json.cgi?PingTest of the component PingTest Handler. The manipulation of the argument pingTestIp/pingTestPktSize/pingTestTimes results in os command injection. The attack can be launched remotely. The exploit is now public and may be used.7h